| Topology | Forward Converter |
| Input voltage | 42.7-57 V |
| Output 1 | 3.3 V / 27 A |
| IC revision | 1.0 |
The GreenBridge™ FDMQ8205A evaluation board demonstrates the polarity protection bridge commonly used at the input of a Power over Ethernet (PoE) Power Device (PD). The protection bridge is used to protect the PD and make it insensitive to the polarity of a power source coupled to the PD. The PD itself may be sensitive to the polarity of the power source, but the bridge rectifier can be configured to provide the proper polarity to the device when the polarity of the power source is reversed. The GreenBridge™ can replace the conventional diode bridge and drastically reduce the power dissipation caused by the large voltage drop of a diode bridge, resulting in a high efficiency power device while not compromising the IEEE802.3at specification. The small package size of MLP4.5x5 reduces PCB area and increases power density.
Active MOSFET bridge with low forward drop to replace conventional diode bridge Self driving circuitry for MOSFETs Low rDS(on) 100V MOSFETs Maximizing available power and voltage IEEE802.3at compliant
Order Code | Datasheet | Simulation | Downloads | Status | Product series | xPxC | Type | Ports | Shielding | Tab | EMI | Application System | Working Voltage(V (AC)) | Packaging | L(µH) | n | IR(A) | ∫Udt(µVs) | VT(V (AC)) | RDC 1(mΩ) | RDC 2(Ω) | Samples | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | WR-MJ Cat 3 Modular Jacks – THT, 8P8C, Horizontal | Simulation– | Status Activei| Production is active. Expected lifetime: >10 years. | Product seriesWR-MJ Cat 3 Modular Jacks – THT | Number of Pins (xPxC)8P8C | TypeHorizontal | Ports1x1 | ShieldingShielded | Tab PositionDown | EMI FingersNo | Application SystemCAT 3 | Working Voltage120 V (AC) | PackagingTray | – | – | Rated Current1.5 A | – | – | – | – | |||
![]() | WE-CST Current Sense Transformer, –, – | Simulation– | Status Activei| Production is active. Expected lifetime: >10 years. | Product seriesWE-CST Current Sense Transformer | – | – | – | – | – | – | – | – | – | Inductance2000 µH | Turns Ratio1:100 | Rated Current20 A | Voltage-µSecond50 µVs | Insulation Test Voltage500 V (AC) | DC Resistance 10.75 mΩ | DC Resistance 25.5 Ω | |||
749022016 | 10/100/1000 Base-T SMT Transformer, –, – | Downloads– | Status Activei| Production is active. Expected lifetime: >10 years. | Product series 10/100/1000 Base-T SMT Transformer | – | – | Ports1 | – | – | – | – | – | – | Inductance350 µH | – | – | – | Insulation Test Voltage1500 V (AC) | – | – |