| Topologie | Sperrwandler |
| Eingangsspannung | 90-460 V |
| Ausgang 1 | 16.5 V / 0.05 A |
| IC-Revision | B |
The PMP7146 has been designed especially for E-meters with PLC (power line communication) on board. The input filter shows high impedance to the PLC transmitter and the controller LM5021 works in constant switching frequency. A settable skip-mode improves the efficiency at light load. Two Bucks and an LDO supply the power to the digital section of the E-meter.
Remark: BOM is added with Schematic pdf.
Artikel Nr. | Datenblatt | Simulation | Downloads | Status | Produktserie | L(µH) | IR(A) | ISAT,10%(A) | RDC max.(Ω) | fres(MHz) | Version | Muster | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | 750811434 | Transformer, 770 µH, – | Status Aktivi| Produktion ist aktiv. Erwartete Lebenszeit: >10 Jahre. | Produktserie Transformer | Induktivität770 µH | – | – | – | – | – | |||
![]() | WE-TI Tonneninduktivität, 1000 µH, 0.42 A | Status Aktivi| Produktion ist aktiv. Erwartete Lebenszeit: >10 Jahre. | ProduktserieWE-TI Tonneninduktivität | Induktivität1000 µH | Nennstrom0.42 A | Sättigungsstrom 10.69 A | Gleichstromwiderstand2.5 Ω | Eigenresonanzfrequenz1.6 MHz | VersionGestanzt |