Controller

Like any integrated circuit the controller will need some peripheral components to make it run properly

Crystal

Keep the XTAL as close as possible to the IC. Where applicable connect the XTAL housing to GND. A via fence reduces coupling to the GND plane. An oscillator can be used alternatively.

Load Capacitor

Load capacitors should be low leakage and stable across temperature range (NP0). For the capacitive load (cload) the stray capacitance of the PCB and the IC pins should be considered:

CL = (C1*C2) / (C1+C2) + Cstray

Cstray ≈ 3…6pF

Digital Isolator

Digital Isolators provide a galvanic isolation of signals and reliable data transmission in high-speed applications with rates up to 150 Mbps. The WPME-CDIx series optionally includes an isolated power supply and provides an isolation voltage of up to 5000VRMS. All part numbers are UL1577 recognized and have VDE 0884-17 and IEC 60747-17 certificates.

Isolated DC/DC Converter

The use of isolated signal lines often facilitates the need for an isolated power supply for sensors or other peripherals. Integrated power modules simplify the design and accelerate the development

SMT Ferrites

On single ended datalines you can use a High Speed SMT Ferrite to improve EMC.

SMT Ferrites

On single ended datalines you can use a High Speed SMT Ferrite to improve EMC.

SMT Ferrites

On single ended datalines you can use a High Speed SMT Ferrite to improve EMC.

SMT Ferrites

On single ended datalines you can use a High Speed SMT Ferrite to improve EMC.

ESD Protection

ESD protection devices should be put right behind the connector. Avoid layer hops to prevent propagation of the ESD.

ESD Protection

ESD protection devices should be put right behind the connector. Avoid layer hops to prevent propagation of the ESD.

ESD Protection

ESD protection devices should be put right behind the connector. Avoid layer hops to prevent propagation of the ESD.

ESD Protection

ESD protection devices should be put right behind the connector. Avoid layer hops to prevent propagation of the ESD.

D-SUB Connector

We can provide the well established D-Sub connector. Not only do we have the male and female version in our portfolio, but with the angled and non angled versions and fitting cable options we can fully support you and your needs.

Terminal Blocks

To further support the needs of our industrial customers we also have a wide range of Terminal Blocks. From a technical aspect we support THT, THR and SMT and we have different pitches, ranging from 2,5mm up to 7,62mm, when looking at our pluggable portfolio. To give you an overview of the fixation types we can offer: Wire Protector, Rising Cage Clamp, Excenter Clamp, Screwless Spring Clamp, Screwless Push In, Pluggable and IDC Clamp.

XTAL Ground

This GND plane should be connected to IC GND and cover all the traces to the XTAL.

image/svg+xml Page-1 Sheet.107 Sheet.108 Sheet.115 Sheet.116 Sheet.121 Sheet.122 Sheet.123 Sheet.124 Sheet.88 Sheet.89 Sheet.90 Sheet.91 Sheet.92 Sheet.93 Sheet.94 Sheet.95 Sheet.96 Sheet.97 Sheet.98 Sheet.99 Sheet.100 Ferrit Sheet.23 Sheet.24 Sheet.25 Sheet.26 Ferrit.27 Sheet.28 Sheet.29 Sheet.30 Sheet.31 Ferrit.32 Sheet.33 Sheet.34 Sheet.35 Sheet.36 Ferrit.37 Sheet.38 Sheet.39 Sheet.40 Sheet.41 Knotenpunkt Sheet.43 Knotenpunkt.44 Sheet.45 Knotenpunkt.46 Sheet.47 Knotenpunkt.48 Sheet.49 Varistor / Suppressor Sheet.51 Widerstand.107 Sheet.53 Sheet.54 Sheet.55 Sheet.56 Varistor / Suppressor.57 Sheet.58 Widerstand.107 Sheet.60 Sheet.61 Sheet.62 Sheet.63 Varistor / Suppressor.64 Sheet.65 Widerstand.107 Sheet.67 Sheet.68 Sheet.69 Sheet.70 Varistor / Suppressor.71 Sheet.72 Widerstand.107 Sheet.74 Sheet.75 Sheet.76 Sheet.77 Knotenpunkt.80 Sheet.81 Knotenpunkt.82 Sheet.83 Knotenpunkt.84 Sheet.85 Knotenpunkt.86 Sheet.87 Masse Sheet.102 Sheet.103 Sheet.1 Controller Sheet.3 TxD Sheet.5 Driver Sheet.6 Tout2 Sheet.7 Tout1 Sheet.8 Rin1 Sheet.9 Rin2 Sheet.78 GND Sheet.106 Sheet.79 Connector Sheet.109 Digital Isolator Sheet.110 OUTB Sheet.111 INA Sheet.113 OUTA Sheet.114 INB Sheet.117 OUTC Sheet.118 OUTD Sheet.119 INC Sheet.120 IND Sheet.127 RTS Sheet.128 CTS Sheet.129 RxD Sheet.130 Isolation Sheet.131 Sheet.132 Sheet.133 Sheet.134 Sheet.135 Sheet.136 Sheet.137 DC Sheet.138 DC Netz Netz.301 Masse.302 Sheet.142 Sheet.143 Masse.305 Sheet.145 Sheet.146 Sheet.147 GND B Sheet.148 GND A Sheet.149 Sheet.150 Sheet.151 Sheet.152 Sheet.153 Quarz Sheet.155 Sheet.156 Sheet.157 Sheet.158 Sheet.159 Sheet.160 Kondensator.173 Sheet.162 Sheet.163 Sheet.164 Sheet.165 Kondensator.178 Sheet.167 Sheet.168 Sheet.169 Sheet.170 Knotenpunkt.171 Sheet.172 Knotenpunkt.189 Sheet.174 Knotenpunkt.191 Sheet.176 Masse.177 Sheet.178 Sheet.179

Short Introduction to RS232

The RS232 (Recommended Standard 232) interface describes the standard for a serial interface which today is mostly only used as a service or configuration interface. The data rate is strongly dependent on the cable length, but has a maximum of 115.2 kBd.

The transmission is asymmetrical and reacts strongly to common mode interferences. Mostly 9-pin D-Sub variants are used as connectors.