| Topologie | Gegentaktwandler (Halbbrücken) |
| Eingangsspannung | 90-305 V |
| Schaltfrequenz | 600 kHz |
| Ausgang 1 | 24 V / 4.16 A |
| IC-Revision | 1.0 |
The HR1001 is an enhanced LLC controller which provides new features of adaptive dead time adjustment (ADTA) and capacitive mode protection (CMP).
The adaptive dead time adjustment automatically inserts a dead time between the two complimentary gate outputs. This is ensured by keeping the outputs off while sensing the dv/dt current of the half-bridgeswitching node. The ADTA features easier design, lower EMI, and higher efficiency.
HR1001 incorporates anti-capacitive mode protection which prevents potentially destructive capacitive mode switching if the output isshorted or has a severe over load. This feature protects the MOSFET during abnormal condition, making the converter robust.
HR1001 has a programmable oscillator that sets both the maximum and minimum switching frequencies. It starts up at a programmedmaximum switching frequency and decays until the control loop takes over to prevent excessive inrush current.
HR1001 enters a controlled burst-mode operation at light-load to minimize the power consumption and tighten output regulation.
HR1001 provides rich protection features which include two-level OCP with external latch shutdown, auto-recovery, brown in/out, CMP, and OTP, improving converter design safety with minimal extra components.
Remarks;L5=180uH L6=14uH And TI UsedRefer page no.22