WE-GDT Gate-Drive-Transformer
SizeDimen­sions3DL
(mm)
W
(mm)
H
(mm)
Mount
EP5
7 8.5 6 SMT
ER9.5
10 12.07 5.97 SMT
1210
10.26 12.98 5.64 SMT

Characteristics

  • Compact package sizes: EP5, ER9.5, 1210 Toroid
  • 1 or 2 secondary windings
  • 7 different Translations
  • Insulation test voltages from 1500 VDC up to 2100 VDC

Applications

  • Suitable for signal and power application
  • Designed for gate drive application high efficient SMPS
  • Synchronous rectification
  • Motor drive control
  • Telecom base station power supplies

Can’t find the suitable product?

We will be glad to help you! We will take your specifications and work to find a solution that fits your needs. Simply fill out our inquiry form with your specifications.

Find your custom solution

Products

All
EP5
ER9.5
1210
Filter article data
Filter by
 show  article in 3 product lines
 article in 3 product lines
Reset all
Order Code
Data­sheet
Downloads
Status
n
L(µH)
∫Udt(µVs)
VT(V (DC))
CWW 1(pF)
LS(µH)
Size
SamplesAvailability & Sample
WE-GDT Gate-Drive-Transformer
760301105
SPEC1:1:1, 260 µH, 25.2 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio1:1:1 
Inductance260 µH
Voltage-µSecond25.2 µVs
Insulation Test Voltage1500 V (DC)
Interwinding Capacitance9 pF
Leakage Inductance1.7 µH
SizeEP5 
Check availability
WE-GDT Gate-Drive-Transformer
760301106
SPEC1:1, 370 µH, 30.2 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio1:1 
Inductance370 µH
Voltage-µSecond30.2 µVs
Insulation Test Voltage1500 V (DC)
Interwinding Capacitance10 pF
Leakage Inductance1.8 µH
SizeEP5 
Check availability
WE-GDT Gate-Drive-Transformer
760301107
SPEC1.5:1, 650 µH, 40.8 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio1.5:1 
Inductance650 µH
Voltage-µSecond40.8 µVs
Insulation Test Voltage1500 V (DC)
Interwinding Capacitance9 pF
Leakage Inductance2.9 µH
SizeEP5 
Check availability
WE-GDT Gate-Drive-Transformer
750316094
SPEC1:1:5:5, 261 µH, 28 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio1:1:5:5 
Inductance261 µH
Voltage-µSecond28 µVs
Insulation Test Voltage2100 V (DC)
Interwinding Capacitance90 pF
Leakage Inductance0.4 µH
Size1210 
Check availability
WE-GDT Gate-Drive-Transformer
750316093
SPEC1:1:2:2, 1710 µH, 70 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio1:1:2:2 
Inductance1710 µH
Voltage-µSecond70 µVs
Insulation Test Voltage2100 V (DC)
Interwinding Capacitance100 pF
Leakage Inductance1.5 µH
Size1210 
Check availability
WE-GDT Gate-Drive-Transformer
750311063
SPEC1:1, 600 µH, 28.7 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio1:1 
Inductance600 µH
Voltage-µSecond28.7 µVs
Insulation Test Voltage2000 V (DC)
Interwinding Capacitance12 pF
Leakage Inductance1.4 µH
SizeER9.5/5 
Check availability
WE-GDT Gate-Drive-Transformer
760301103
SPEC2.5:1:1, 350 µH, 29.4 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio2.5:1:1 
Inductance350 µH
Voltage-µSecond29.4 µVs
Insulation Test Voltage1500 V (DC)
Interwinding Capacitance7 pF
Leakage Inductance2.3 µH
SizeEP5 
Check availability
WE-GDT Gate-Drive-Transformer
760301104
SPEC2:1:1, 330 µH, 28.6 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio2:1:1 
Inductance330 µH
Voltage-µSecond28.6 µVs
Insulation Test Voltage1500 V (DC)
Interwinding Capacitance7 pF
Leakage Inductance1.9 µH
SizeEP5 
Check availability
WE-GDT Gate-Drive-Transformer
760301108
SPEC2.5:1, 460 µH, 33.6 µVs
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Turns Ratio2.5:1 
Inductance460 µH
Voltage-µSecond33.6 µVs
Insulation Test Voltage1500 V (DC)
Interwinding Capacitance9 pF
Leakage Inductance2.3 µH
SizeEP5 
Check availability