Design Kit WE-KI SMT Wire Wound Ceramic Inductor 0402 - ±2% Tol.
Order Code 744765G
Characteristics
- 1 size, 36 values, 1080 components
Products
Filter by
show
in
article
in
0 product lines
Reset all
|
Order Code
|
Datasheet
|
Simulation
|
Downloads
|
Status
|
Product series
|
L
(nH)
|
Qmin.
|
RDC max.
(Ω)
|
IR
(mA)
|
fres
(MHz)
|
Samples
|
|---|---|---|---|---|---|---|---|---|---|---|---|
| WE-KI SMT Wire Wound Ceramic Inductor, 1 nH, 13 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
1 nH
|
Q-Factor
13
|
DC Resistance
0.045 Ω
|
Rated Current
1360 mA
|
Self Resonant Frequency
6000 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 2 nH, 16 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
2 nH
|
Q-Factor
16
|
DC Resistance
0.07 Ω
|
Rated Current
1040 mA
|
Self Resonant Frequency
6000 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 2.2 nH, 18 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
2.2 nH
|
Q-Factor
18
|
DC Resistance
0.07 Ω
|
Rated Current
960 mA
|
Self Resonant Frequency
6000 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 2.7 nH, 16 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
2.7 nH
|
Q-Factor
16
|
DC Resistance
0.12 Ω
|
Rated Current
640 mA
|
Self Resonant Frequency
6000 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 3.3 nH, 20 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
3.3 nH
|
Q-Factor
20
|
DC Resistance
0.066 Ω
|
Rated Current
840 mA
|
Self Resonant Frequency
6000 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 4.7 nH, 15 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
4.7 nH
|
Q-Factor
15
|
DC Resistance
0.13 Ω
|
Rated Current
640 mA
|
Self Resonant Frequency
4775 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 5.1 nH, 23 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
5.1 nH
|
Q-Factor
23
|
DC Resistance
0.083 Ω
|
Rated Current
800 mA
|
Self Resonant Frequency
5800 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 5.6 nH, 23 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
5.6 nH
|
Q-Factor
23
|
DC Resistance
0.083 Ω
|
Rated Current
760 mA
|
Self Resonant Frequency
5800 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 6.8 nH, 20 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
6.8 nH
|
Q-Factor
20
|
DC Resistance
0.083 Ω
|
Rated Current
680 mA
|
Self Resonant Frequency
4800 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 7.5 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
7.5 nH
|
Q-Factor
25
|
DC Resistance
0.104 Ω
|
Rated Current
680 mA
|
Self Resonant Frequency
5800 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 8.2 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
8.2 nH
|
Q-Factor
25
|
DC Resistance
0.104 Ω
|
Rated Current
680 mA
|
Self Resonant Frequency
4400 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 9 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
9 nH
|
Q-Factor
25
|
DC Resistance
0.104 Ω
|
Rated Current
680 mA
|
Self Resonant Frequency
4160 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 10 nH, 23 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
10 nH
|
Q-Factor
23
|
DC Resistance
0.195 Ω
|
Rated Current
480 mA
|
Self Resonant Frequency
3900 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 12 nH, 26 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
12 nH
|
Q-Factor
26
|
DC Resistance
0.12 Ω
|
Rated Current
640 mA
|
Self Resonant Frequency
3600 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 13 nH, 24 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
13 nH
|
Q-Factor
24
|
DC Resistance
0.21 Ω
|
Rated Current
560 mA
|
Self Resonant Frequency
3450 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 15 nH, 26 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
15 nH
|
Q-Factor
26
|
DC Resistance
0.172 Ω
|
Rated Current
560 mA
|
Self Resonant Frequency
3280 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 18 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
18 nH
|
Q-Factor
25
|
DC Resistance
0.23 Ω
|
Rated Current
420 mA
|
Self Resonant Frequency
3100 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 19 nH, 26 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
19 nH
|
Q-Factor
26
|
DC Resistance
0.202 Ω
|
Rated Current
480 mA
|
Self Resonant Frequency
3040 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 20 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
20 nH
|
Q-Factor
25
|
DC Resistance
0.25 Ω
|
Rated Current
420 mA
|
Self Resonant Frequency
3000 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 22 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
22 nH
|
Q-Factor
25
|
DC Resistance
0.3 Ω
|
Rated Current
400 mA
|
Self Resonant Frequency
2800 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 24 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
24 nH
|
Q-Factor
25
|
DC Resistance
0.3 Ω
|
Rated Current
400 mA
|
Self Resonant Frequency
2700 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 27 nH, 26 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
27 nH
|
Q-Factor
26
|
DC Resistance
0.298 Ω
|
Rated Current
400 mA
|
Self Resonant Frequency
2480 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 30 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
30 nH
|
Q-Factor
25
|
DC Resistance
0.3 Ω
|
Rated Current
400 mA
|
Self Resonant Frequency
2350 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 33 nH, 24 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
33 nH
|
Q-Factor
24
|
DC Resistance
0.35 Ω
|
Rated Current
400 mA
|
Self Resonant Frequency
2350 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 36 nH, 26 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
36 nH
|
Q-Factor
26
|
DC Resistance
0.403 Ω
|
Rated Current
320 mA
|
Self Resonant Frequency
2320 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 39 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
39 nH
|
Q-Factor
25
|
DC Resistance
0.55 Ω
|
Rated Current
320 mA
|
Self Resonant Frequency
2100 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 43 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
43 nH
|
Q-Factor
25
|
DC Resistance
0.81 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
2030 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 47 nH, 26 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
47 nH
|
Q-Factor
26
|
DC Resistance
0.83 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
2100 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 51 nH, 25 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
51 nH
|
Q-Factor
25
|
DC Resistance
0.82 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
1750 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 56 nH, 22 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
56 nH
|
Q-Factor
22
|
DC Resistance
0.97 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
1760 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 68 nH, 22 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
68 nH
|
Q-Factor
22
|
DC Resistance
1.12 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
1620 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 75 nH, 20 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
75 nH
|
Q-Factor
20
|
DC Resistance
1.2 Ω
|
Rated Current
160 mA
|
Self Resonant Frequency
1550 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 82 nH, 20 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
82 nH
|
Q-Factor
20
|
DC Resistance
1.25 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
1500 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 91 nH, 20 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
91 nH
|
Q-Factor
20
|
DC Resistance
2.3 Ω
|
Rated Current
120 mA
|
Self Resonant Frequency
1350 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 100 nH, 20 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
100 nH
|
Q-Factor
20
|
DC Resistance
2.52 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
1300 MHz
|
|
|||
| WE-KI SMT Wire Wound Ceramic Inductor, 120 nH, 20 |
Status
Active
i
| Production is active. Expected lifetime: >10 years.
|
Product series
WE-KI SMT Wire Wound Ceramic Inductor
|
Inductance
120 nH
|
Q-Factor
20
|
DC Resistance
2.66 Ω
|
Rated Current
100 mA
|
Self Resonant Frequency
1100 MHz
|
|