Design Kit WE-KI SMT Wire Wound Ceramic Inductor 0805/1008 - ±2% Tol.

Order Code 744762G

Characteristics

  • 2 sizes, 36 values, 1080 components

Products

Filter article data
Filter by
 show  article in 0 product lines
 article in 0 product lines
Reset all
Order Code
Data­sheet
Simu­lation
Downloads
Status
Product series
L(nH)
Qmin.
RDC max.(Ω)
IR(mA)
fres(MHz)
Samples
WE-KI SMT Wire Wound Ceramic Inductor, 2.2 nH, 50
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance2.2 nH
Q-Factor50 
DC Resistance0.06 Ω
Rated Current800 mA
Self Resonant Frequency6000 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 3.3 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance3.3 nH
Q-Factor60 
DC Resistance0.08 Ω
Rated Current800 mA
Self Resonant Frequency6000 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 5.6 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance5.6 nH
Q-Factor60 
DC Resistance0.08 Ω
Rated Current600 mA
Self Resonant Frequency5800 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 6.8 nH, 50
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance6.8 nH
Q-Factor50 
DC Resistance0.06 Ω
Rated Current1000 mA
Self Resonant Frequency5500 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 8.2 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance8.2 nH
Q-Factor60 
DC Resistance0.06 Ω
Rated Current600 mA
Self Resonant Frequency5500 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 10 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance10 nH
Q-Factor60 
DC Resistance0.08 Ω
Rated Current600 mA
Self Resonant Frequency4800 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 10 nH, 50
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance10 nH
Q-Factor50 
DC Resistance0.08 Ω
Rated Current1000 mA
Self Resonant Frequency4300 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 12 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance12 nH
Q-Factor60 
DC Resistance0.08 Ω
Rated Current600 mA
Self Resonant Frequency4100 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 15 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance15 nH
Q-Factor60 
DC Resistance0.08 Ω
Rated Current600 mA
Self Resonant Frequency3600 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 15 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance15 nH
Q-Factor60 
DC Resistance0.08 Ω
Rated Current1000 mA
Self Resonant Frequency2700 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 18 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance18 nH
Q-Factor60 
DC Resistance0.1 Ω
Rated Current1000 mA
Self Resonant Frequency2700 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 22 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance22 nH
Q-Factor60 
DC Resistance0.1 Ω
Rated Current600 mA
Self Resonant Frequency3300 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 27 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance27 nH
Q-Factor60 
DC Resistance0.1 Ω
Rated Current1000 mA
Self Resonant Frequency1800 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 33 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance33 nH
Q-Factor60 
DC Resistance0.15 Ω
Rated Current500 mA
Self Resonant Frequency2400 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 33 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance33 nH
Q-Factor60 
DC Resistance0.1 Ω
Rated Current1000 mA
Self Resonant Frequency1700 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 39 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance39 nH
Q-Factor60 
DC Resistance0.18 Ω
Rated Current500 mA
Self Resonant Frequency2100 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 39 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance39 nH
Q-Factor60 
DC Resistance0.1 Ω
Rated Current1000 mA
Self Resonant Frequency1500 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 47 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance47 nH
Q-Factor60 
DC Resistance0.15 Ω
Rated Current500 mA
Self Resonant Frequency1700 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 56 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance56 nH
Q-Factor60 
DC Resistance0.12 Ω
Rated Current1000 mA
Self Resonant Frequency1350 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 68 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance68 nH
Q-Factor60 
DC Resistance0.27 Ω
Rated Current500 mA
Self Resonant Frequency1450 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 82 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance82 nH
Q-Factor60 
DC Resistance0.32 Ω
Rated Current500 mA
Self Resonant Frequency1350 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 82 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance82 nH
Q-Factor60 
DC Resistance0.18 Ω
Rated Current1000 mA
Self Resonant Frequency1100 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 100 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance100 nH
Q-Factor60 
DC Resistance0.43 Ω
Rated Current500 mA
Self Resonant Frequency1200 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 100 nH, 60
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance100 nH
Q-Factor60 
DC Resistance0.18 Ω
Rated Current1000 mA
Self Resonant Frequency1100 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 120 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance120 nH
Q-Factor45 
DC Resistance0.2 Ω
Rated Current800 mA
Self Resonant Frequency950 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 150 nH, 50
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance150 nH
Q-Factor50 
DC Resistance0.56 Ω
Rated Current400 mA
Self Resonant Frequency950 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 180 nH, 50
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance180 nH
Q-Factor50 
DC Resistance0.78 Ω
Rated Current400 mA
Self Resonant Frequency900 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 180 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance180 nH
Q-Factor45 
DC Resistance0.33 Ω
Rated Current800 mA
Self Resonant Frequency800 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 220 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance220 nH
Q-Factor45 
DC Resistance0.45 Ω
Rated Current800 mA
Self Resonant Frequency730 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 270 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance270 nH
Q-Factor45 
DC Resistance1.46 Ω
Rated Current350 mA
Self Resonant Frequency850 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 330 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance330 nH
Q-Factor45 
DC Resistance0.9 Ω
Rated Current500 mA
Self Resonant Frequency570 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 390 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance390 nH
Q-Factor45 
DC Resistance2.2 Ω
Rated Current210 mA
Self Resonant Frequency780 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 560 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance560 nH
Q-Factor45 
DC Resistance1.5 Ω
Rated Current310 mA
Self Resonant Frequency430 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 680 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance680 nH
Q-Factor45 
DC Resistance2.06 Ω
Rated Current230 mA
Self Resonant Frequency380 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 820 nH, 45
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance820 nH
Q-Factor45 
DC Resistance2.3 Ω
Rated Current180 mA
Self Resonant Frequency350 MHz
WE-KI SMT Wire Wound Ceramic Inductor, 1000 nH, 35
Simu­lation
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance1000 nH
Q-Factor35 
DC Resistance3.3 Ω
Rated Current120 mA
Self Resonant Frequency310 MHz