WE-IBTI Isolated Buck Transformers

Characteristics

Applications

  • Industrial Programmable Logic Controllers (PLCs)
  • Building automation and process control
  • Isolated interface power: RS-422, RS-485, CAN, I2C, LAN
  • Motor drive control, inverters and industrial automation
  • Isolated low power drivers & regulators, smart e-meters
  • Bias power supplies for gate drives and op-amps

Can’t find the suitable product?

We will be glad to help you! We will take your specifications and work to find a solution that fits your needs. Simply fill out our inquiry form with your specifications.

Find your custom solution

Products

All
EP5
EP7
EP10
EP13
EE16/8/5
EE20/10/6
EFD20
ER9.5S
ER11.5
PQ2020
Filter article data
Filter by
 show  article in 10 product lines
 article in 10 product lines
Reset all
Log in now to view availability and request availability forecasts. LOGIN
Order Code
Data­sheet
Simu­lation
Downloads
Status
VIN(V)
VOut1(V)
IOut1(A)
VOut2(V)
IOut2(A)
VOut3(V)
IOut3(A)
VOut4(V)
IOut4(mA)
Vaux(V)
Vbuck(V)
L(µH)
NPRI : NSEC
ISAT(A)
LS(nH)
VT(V (AC))
fswitch(kHz)
Mount
L(mm)
W(mm)
H(mm)
SamplesAvailability & Sample
Log in now to view availability and request availability forecasts. LOGIN
WE-IBTI Isolated Buck Transformers
750311780
SPEC2.5 - 3.5 V (DC), 15 V, 0.2 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 2.5 - 3.5 V (DC)
Output Voltage 115 V
Output Current 10.2 A
Output Voltage 215 V
Output Current 20.2 A
Inductance2 µH
Turns Ratio1:8:8 
Saturation Current10 A
Leakage Inductance200 nH
Insulation Test Voltage2000 V (AC)
Switching Frequency 500
MountSMT 
Length9.78 mm
Width9.14 mm
Height10.54 mm
WE-IBTI Isolated Buck Transformers
750312547
SPEC3 - 6 V (DC), 5 V, 0.2 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 3 - 6 V (DC)
Output Voltage 15 V
Output Current 10.2 A
Inductance1 µH
Turns Ratio1:2.4 
Saturation Current2 A
Leakage Inductance70 nH
Insulation Test Voltage3000 V (AC)
Switching Frequency 500
MountSMT 
Length9.78 mm
Width9.14 mm
Height10.54 mm
WE-IBTI Isolated Buck Transformers
750311880
SPEC3 - 6 V (DC), 5 V, 0.2 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 3 - 6 V (DC)
Output Voltage 15 V
Output Current 10.2 A
Inductance2.5 µH
Turns Ratio1:2.5 
Saturation Current12 A
Leakage Inductance125 nH
Insulation Test Voltage2500 V (AC)
Switching Frequency 200 - 600
MountSMT 
Length9.78 mm
Width9.14 mm
Height10.54 mm
WE-IBTI Isolated Buck Transformers
750316170
SPEC3.5 - 5.5 V (DC), 13.5 V, 0.01 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 3.5 - 5.5 V (DC)
Output Voltage 113.5 V
Output Current 10.01 A
Output Voltage 2-13.5 V
Output Current 20.01 A
Output Voltage 35 V
Output Current 30.1 A
Buck Voltage2.17 V
Inductance2.7 µH
Turns Ratio1:8:8:3 
Saturation Current7 A
Leakage Inductance500 nH
Insulation Test Voltage1875 V (AC)
Switching Frequency 400
MountSMT 
Length9.78 mm
Width9.5 mm
Height10.54 mm
WE-IBTI Isolated Buck Transformers
750315703
SPEC5 - 15 V (DC), 5 V, 0.5 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 5 - 15 V (DC)
Output Voltage 15 V
Output Current 10.5 A
Buck Voltage4.5 V
Inductance25 µH
Turns Ratio1:1 
Saturation Current1 A
Leakage Inductance380 nH
Insulation Test Voltage2500 V (AC)
Switching Frequency 200
MountSMT 
Length9.78 mm
Width9.5 mm
Height10.54 mm
WE-IBTI Isolated Buck Transformers
750315038
SPEC7 - 26 V (DC), 23 V, 0.3 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 7 - 26 V (DC)
Output Voltage 123 V
Output Current 10.3 A
Output Voltage 223 V
Output Current 20.1 A
Output Voltage 323 V
Output Current 30.1 A
Output Voltage 423 V
Output Current 4100 mA
Buck Voltage10.5 V
Inductance36.5 µH
Turns Ratio1:2.33:2.33:2.33:2.33 
Leakage Inductance300 nH
Insulation Test Voltage3600 V (AC)
Switching Frequency 250 - 600
MountTHT 
Length23.36 mm
Width23.88 mm
Height24.14 mm
WE-IBTI Isolated Buck Transformers
750342627
SPEC9 - 15 V (DC), 9 V, 0.25 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 9 - 15 V (DC)
Output Voltage 19 V
Output Current 10.25 A
Inductance20 µH
Turns Ratio2.4:1 
Saturation Current2 A
Leakage Inductance270 nH
Insulation Test Voltage4500 V (AC)
Switching Frequency 200 - 350
MountTHT 
Length20.32 mm
Width24.38 mm
Height16 mm
WE-IBTI Isolated Buck Transformers
750314597
SPEC10 - 40 V (DC), 15.5 V, 0.25 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 10 - 40 V (DC)
Output Voltage 115.5 V
Output Current 10.25 A
Buck Voltage8 V
Inductance60 µH
Turns Ratio1:1.5 
Saturation Current0.84 A
Leakage Inductance1200 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 150
MountSMT 
Length10.16 mm
Width13.36 mm
Height8.64 mm
WE-IBTI Isolated Buck Transformers
750314952
SPEC10 - 40 V (DC), 3.3 V, 0.15 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 10 - 40 V (DC)
Output Voltage 13.3 V
Output Current 10.15 A
Buck Voltage3.3 V
Inductance2500 µH
Turns Ratio1:1.25 
Insulation Test Voltage2000 V (AC)
Switching Frequency 100
MountSMT 
Length9.78 mm
Width9.14 mm
Height10.54 mm
WE-IBTI Isolated Buck Transformers
750316586
SPEC10 - 14 V (DC), 7 V, 0.3 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 10 - 14 V (DC)
Output Voltage 17 V
Output Current 10.3 A
Output Voltage 212 V
Output Current 20.05 A
Output Voltage 330 V
Output Current 30.075 A
Buck Voltage-12 V
Inductance150 µH
Turns Ratio1.69:1:1.69:4.07 
Saturation Current1.3 A
Leakage Inductance1700 nH
Insulation Test Voltage4000 V (AC)
Switching Frequency 200
MountTHT 
Length22.2 mm
Width25 mm
Height16 mm
WE-IBTI Isolated Buck Transformers
750315393
SPEC11.8 - 13.2 V (DC), 12 V, 0.6 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 11.8 - 13.2 V (DC)
Output Voltage 112 V
Output Current 10.6 A
Buck Voltage4.2 V
Inductance37.5 µH
Turns Ratio1:3 
Saturation Current3 A
Leakage Inductance400 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 600
MountTHT 
Length17.96 mm
Width20.3 mm
Height14.3 mm
WE-IBTI Isolated Buck Transformers
750315144
SPEC12 - 36 V (DC), -17.5 V, 0.03 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 12 - 36 V (DC)
Output Voltage 1-17.5 V
Output Current 10.03 A
Output Voltage 217.5 V
Output Current 20.045 A
Buck Voltage9 V
Inductance80 µH
Turns Ratio1:2:2 
Saturation Current0.5 A
Leakage Inductance2100 nH
Insulation Test Voltage490 V (AC)
Switching Frequency 300
MountSMT 
Length10 mm
Width14 mm
Height5 mm
WE-IBTI Isolated Buck Transformers
750315547
SPEC12 - 48 V (DC), 3.6 V, 0.1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 12 - 48 V (DC)
Output Voltage 13.6 V
Output Current 10.1 A
Buck Voltage3.3 V
Inductance42 µH
Turns Ratio1:1.2 
Saturation Current1.1 A
Leakage Inductance800 nH
Insulation Test Voltage2500 V (AC)
Switching Frequency 300
MountSMT 
Length9.78 mm
Width9.14 mm
Height10.54 mm
WE-IBTI Isolated Buck Transformers
750314851
SPEC14 - 40 V (DC), 14 V, 0.1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 14 - 40 V (DC)
Output Voltage 114 V
Output Current 10.1 A
Output Voltage 25 V
Output Current 20.05 A
Output Voltage 314 V
Output Current 30.05 A
Output Voltage 45 V
Output Current 450 mA
Buck Voltage10.2 V
Inductance68 µH
Turns Ratio1.83:1.67:1:1.67:1 
Saturation Current1.8 A
Leakage Inductance1200 nH
Insulation Test Voltage4000 V (AC)
Switching Frequency 300
MountSMT 
Length17.78 mm
Width26.1 mm
Height13.8 mm
WE-IBTI Isolated Buck Transformers
750314225
SPEC15 - 40 V (DC), 5 V, 0.25 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 15 - 40 V (DC)
Output Voltage 15 V
Output Current 10.25 A
Output Voltage 25 V
Output Current 20.25 A
Buck Voltage7.8 V
Inductance50 µH
Turns Ratio1.5:1 
Saturation Current1.3 A
Leakage Inductance800 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 250 - 600
MountSMT 
Length13.34 mm
Width15.24 mm
Height11.43 mm
WE-IBTI Isolated Buck Transformers
750314226
SPEC15 - 40 V (DC), 15 V, 0.15 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 15 - 40 V (DC)
Output Voltage 115 V
Output Current 10.15 A
Output Voltage 215 V
Output Current 20.15 A
Buck Voltage7.8 V
Inductance33.8 µH
Turns Ratio2:1 
Saturation Current1 A
Leakage Inductance150 nH
Insulation Test Voltage1875 V (AC)
Switching Frequency 250 - 600
MountSMT 
Length13.34 mm
Width15.24 mm
Height11.43 mm
WE-IBTI Isolated Buck Transformers
750342156
SPEC15 - 40 V (DC), 12.7 V, 0.6 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 15 - 40 V (DC)
Output Voltage 112.7 V
Output Current 10.6 A
Output Voltage 212.7 V
Output Current 20.6 A
Inductance66 µH
Turns Ratio1:1 
Saturation Current1.2 A
Leakage Inductance1500 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 600
MountSMT 
Length13.34 mm
Width15.24 mm
Height11.43 mm
WE-IBTI Isolated Buck Transformers
750313995
SPEC15 - 40, 15 V, 0.05 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 15 - 40
Output Voltage 115 V
Output Current 10.05 A
Output Voltage 25 V
Output Current 20.1 A
Output Voltage 35 V
Output Current 30.1 A
Output Voltage 415 V
Output Current 450 mA
Buck Voltage7.8 V
Inductance50 µH
Turns Ratio1.5:1:1:2:2 
Saturation Current1.5 A
Leakage Inductance260 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 300 - 600
MountSMT 
Length13.46 mm
Width17.75 mm
Height12.7 mm
WE-IBTI Isolated Buck Transformers
750314442
SPEC16 - 36 V (DC), 10 V, 0.025 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 110 V
Output Current 10.025 A
Output Voltage 25 V
Output Current 20.08 A
Output Voltage 3-5 V
Output Current 30.08 A
Output Voltage 4-10 V
Output Current 425 mA
Buck Voltage13 V
Inductance45 µH
Turns Ratio2.08:2:1:2:1 
Saturation Current0.78 A
Leakage Inductance930 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 200 - 350
MountSMT 
Length12.95 mm
Width12.7 mm
Height5.98 mm
WE-IBTI Isolated Buck Transformers
750314459
SPEC16 - 36 V (DC), 7 V, 0.03 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 17 V
Output Current 10.03 A
Output Voltage 25 V
Output Current 20.08 A
Output Voltage 3-5 V
Output Current 30.08 A
Output Voltage 4-7 V
Output Current 430 mA
Buck Voltage13 V
Inductance45 µH
Turns Ratio1.79:1.29:1:1.29:1 
Saturation Current0.8 A
Leakage Inductance1000 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 200 - 350
MountSMT 
Length12.95 mm
Width12.7 mm
Height5.98 mm
WE-IBTI Isolated Buck Transformers
750314460
SPEC16 - 36 V (DC), 12 V, 0.03 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 112 V
Output Current 10.03 A
Output Voltage 212 V
Output Current 20.03 A
Output Voltage 3-5 V
Output Current 30.08 A
Output Voltage 4-5 V
Output Current 480 mA
Buck Voltage13 V
Inductance45 µH
Turns Ratio1.79:2.29:2.29:1:1 
Saturation Current0.9 A
Leakage Inductance910 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 200 - 350
MountSMT 
Length12.95 mm
Width12.7 mm
Height5.98 mm
WE-IBTI Isolated Buck Transformers
750314461
SPEC16 - 36 V (DC), 15 V, 0.033 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 115 V
Output Current 10.033 A
Output Voltage 25 V
Output Current 20.1 A
Output Voltage 3-5 V
Output Current 30.1 A
Buck Voltage13 V
Inductance45 µH
Turns Ratio1.92:3:1:1 
Saturation Current0.96 A
Leakage Inductance400 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 200 - 350
MountSMT 
Length12.95 mm
Width12.7 mm
Height5.98 mm
WE-IBTI Isolated Buck Transformers
750314462
SPEC16 - 36 V (DC), 5 V, 0.1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 15 V
Output Current 10.1 A
Output Voltage 212 V
Output Current 20.04 A
Output Voltage 3-12 V
Output Current 30.04 A
Buck Voltage13 V
Inductance45 µH
Turns Ratio1.92:1:2.38:2.38 
Saturation Current0.98 A
Leakage Inductance450 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 200 - 350
MountSMT 
Length12.95 mm
Width12.7 mm
Height5.98 mm
WE-IBTI Isolated Buck Transformers
750314463
SPEC16 - 36 V (DC), 24 V, 0.02 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 124 V
Output Current 10.02 A
Output Voltage 212 V
Output Current 20.04 A
Output Voltage 3-12 V
Output Current 30.04 A
Buck Voltage13 V
Inductance45 µH
Turns Ratio1:2.36:1.16:1.16 
Saturation Current0.96 A
Leakage Inductance450 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 200 - 350
MountSMT 
Length12.95 mm
Width12.7 mm
Height5.98 mm
WE-IBTI Isolated Buck Transformers
750315246
SPEC16 - 36 V (DC), 5 V, 0.2 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 15 V
Output Current 10.2 A
Buck Voltage5 V
Inductance26 µH
Turns Ratio1:1.09 
Saturation Current0.96 A
Leakage Inductance650 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 350
MountSMT 
Length10 mm
Width14 mm
Height5 mm
WE-IBTI Isolated Buck Transformers
750315856
SPEC16 - 36 V (DC), 27 V, 0.04 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 16 - 36 V (DC)
Output Voltage 127 V
Output Current 10.04 A
Output Voltage 25 V
Output Current 20.05 A
Output Voltage 3-5 V
Output Current 30.02 A
Buck Voltage9 V
Inductance120 µH
Turns Ratio1 : 3 : 0.56 : 0.56 
Saturation Current0.65 A
Leakage Inductance5000 nH
Insulation Test Voltage625 V (AC)
Switching Frequency 250
MountSMT 
Length12.95 mm
Width12.85 mm
Height6.35 mm
WE-IBTI Isolated Buck Transformers
750314624
SPEC17 - 35 V (DC), 9 V, 0.1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 17 - 35 V (DC)
Output Voltage 19 V
Output Current 10.1 A
Output Voltage 216 V
Output Current 20.1 A
Output Voltage 39 V
Output Current 30.1 A
Output Voltage 416 V
Output Current 4100 mA
Buck Voltage10.3 V
Inductance60 µH
Turns Ratio1.08:1:1.75:1:1.75 
Saturation Current1.55 A
Leakage Inductance800 nH
Insulation Test Voltage5000 V (AC)
Switching Frequency 250 - 600
MountTHT 
Length22.2 mm
Width25 mm
Height16 mm
WE-IBTI Isolated Buck Transformers
750342206
SPEC18 - 24 V (DC), 15 V, 0.15 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 18 - 24 V (DC)
Output Voltage 115 V
Output Current 10.15 A
Output Voltage 25 V
Output Current 20.1 A
Output Voltage 315 V
Output Current 30.15 A
Auxiliary Voltage5 V
Inductance50 µH
Turns Ratio2 : 3 : 1 : 3.2 : 1 
Insulation Test Voltage1500 V (AC)
Switching Frequency 200 - 400
MountSMT 
Length12.95 mm
Width12.85 mm
Height6.35 mm
WE-IBTI Isolated Buck Transformers
750317963
SPEC18 - 60 V (DC), 25 V, 0.06 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 18 - 60 V (DC)
Output Voltage 125 V
Output Current 10.06 A
Output Voltage 225 V
Output Current 20.06 A
Output Voltage 325 V
Output Current 30.06 A
Output Voltage 425 V
Output Current 460 mA
Inductance22 µH
Turns Ratio0.5:1:1:1:1 
Saturation Current2.4 A
Leakage Inductance200 nH
Insulation Test Voltage1000 V (AC)
Switching Frequency 220 - 350
MountTHT 
Length13.97 mm
Width15.37 mm
Height12.7 mm
WE-IBTI Isolated Buck Transformers
750315039
SPEC19 - 30 V (DC), 5 V, 1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 19 - 30 V (DC)
Output Voltage 15 V
Output Current 11 A
Output Voltage 215 V
Output Current 20.2 A
Output Voltage 315 V
Output Current 30.2 A
Buck Voltage7.65 V
Inductance40 µH
Turns Ratio1.43:1:2.86:2.86 
Saturation Current1.8 A
Leakage Inductance300 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 250
MountSMT 
Length23.11 mm
Width29.08 mm
Height11.43 mm
WE-IBTI Isolated Buck Transformers
750312750
SPEC20 - 100 V (DC), 10 V, 0.3 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 20 - 100 V (DC)
Output Voltage 110 V
Output Current 10.3 A
Buck Voltage10 V
Inductance23 µH
Turns Ratio1:1 
Saturation Current0.76 A
Leakage Inductance400 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 750
MountSMT 
Length6.6 mm
Width8.26 mm
Height5.59 mm
WE-IBTI Isolated Buck Transformers
750315245
SPEC20 - 30 V (DC), 5 V, 0.2 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 20 - 30 V (DC)
Output Voltage 15 V
Output Current 10.2 A
Buck Voltage5.5 V
Inductance30 µH
Turns Ratio1:1 
Saturation Current0.96 A
Leakage Inductance750 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 350
MountSMT 
Length10 mm
Width14 mm
Height5 mm
WE-IBTI Isolated Buck Transformers
750315247
SPEC20 - 30 V (DC), 15 V, 0.1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 20 - 30 V (DC)
Output Voltage 115 V
Output Current 10.1 A
Buck Voltage7.8 V
Inductance30 µH
Turns Ratio1:2 
Saturation Current0.88 A
Leakage Inductance825 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 350
MountSMT 
Length10 mm
Width14 mm
Height5 mm
WE-IBTI Isolated Buck Transformers
750315248
SPEC20 - 30 V (DC), -5 V, 0.1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 20 - 30 V (DC)
Output Voltage 1-5 V
Output Current 10.1 A
Output Voltage 25 V
Output Current 20.1 A
Buck Voltage5.5 V
Inductance30 µH
Turns Ratio1:1:1 
Saturation Current0.96 A
Leakage Inductance750 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 350
MountSMT 
Length10 mm
Width14 mm
Height5 mm
WE-IBTI Isolated Buck Transformers
750315249
SPEC20 - 30 V (DC), -15 V, 0.05 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 20 - 30 V (DC)
Output Voltage 1-15 V
Output Current 10.05 A
Output Voltage 215 V
Output Current 20.05 A
Buck Voltage10.4 V
Inductance30 µH
Turns Ratio1:1.5:1.5 
Saturation Current0.92 A
Leakage Inductance900 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 350
MountSMT 
Length10 mm
Width14 mm
Height5 mm
WE-IBTI Isolated Buck Transformers
750315250
SPEC20 - 30 V (DC), -5 V, 0.1 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 20 - 30 V (DC)
Output Voltage 1-5 V
Output Current 10.1 A
Output Voltage 25 V
Output Current 20.1 A
Buck Voltage11 V
Inductance30 µH
Turns Ratio2:1:1 
Saturation Current0.9 A
Leakage Inductance825 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 350
MountSMT 
Length10 mm
Width14 mm
Height5 mm
WE-IBTI Isolated Buck Transformers
750312924
SPEC36 - 75 V (DC), 10 V, 0.12 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 36 - 75 V (DC)
Output Voltage 110 V
Output Current 10.12 A
Output Voltage 25 V
Output Current 20.08 A
Buck Voltage10 V
Inductance26 µH
Turns Ratio2:2:1 
Saturation Current0.55 A
Leakage Inductance1000 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 750
MountSMT 
Length8.35 mm
Width9.5 mm
Height6.35 mm
WE-IBTI Isolated Buck Transformers
750315811
SPEC36 - 72 V (DC), 12 V, 0.83 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 36 - 72 V (DC)
Output Voltage 112 V
Output Current 10.83 A
Buck Voltage12 V
Inductance60 µH
Turns Ratio1:1 
Saturation Current2.1 A
Leakage Inductance1700 nH
Insulation Test Voltage1500 V (AC)
Switching Frequency 300
MountSMT 
Length13.34 mm
Width15.24 mm
Height11.43 mm
WE-IBTI Isolated Buck Transformers
750344207
SPEC36 - 75 V (DC), 9 V, 0.05 A
Simu­lation
Availability
Status Activei| Production is active. Expected lifetime: >10 years.
Input Voltage 36 - 75 V (DC)
Output Voltage 19 V
Output Current 10.05 A
Buck Voltage9 V
Inductance150 µH
Turns Ratio1:1 
Leakage Inductance3400 nH
Insulation Test Voltage3000 V (AC)
Switching Frequency 600
MountSMT 
Length12.4 mm
Width13.8 mm
Height13.6 mm