Size Dimen­sions 3D L
(mm)
W
(mm)
H
(mm)
ER11/5
12.9 13 6.2
ER14.5/6
16.3 16.8 7.4
EFD15
17.5 22.1 8.3
EFD20
21 29.5 10.8

Characteristics

  • Transformer with 6 identical windings
  • 4 sizes with 5 different lengths of air gap each
  • Isolation voltage 500 VDC
  • Low leakage inductance
  • Operating temperature: –40 ºC to +125 ºC
  • By using different circuits more than 375 transformer solutions and about 125 choke solutions possible. Consequently, quick prototyping possibilities

Applications

  • All kind of switching regulators
    - Flyback converters
    - Forward converters
    - Push-pull converters
    - Step-up/step-down converters
    - SEPIC converter

Can’t find the suitable product?

We will be glad to help you! We will take your specifications and work to find a solution that fits your needs. Simply fill out our inquiry form with your specifications.

Find your custom solution

Products

All
ER11/5
ER14.5/6
EFD15
EFD20
Filter article data
Filter by
 show   article  in  4 product lines
 article  in  4 product lines
Reset all
Order Code
Data­sheet
Downloads
Status
LBASE (µH)
IR BASE (A)
ISAT BASE (A)
n
VT (V (AC))
∫Udt Base (µVs)
RDC BASE (mΩ)
Size
Type
Samples
WE-FLEX Flexible Transformer for DC/DC Converter
749196540
3.4 µH, 1.91 A, 4.18 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 3.4 µH
Rated Current Base 1.91 A
Saturation Current Base 4.18 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 65.6 µVs
DC Resistance Base 30 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196530
4.3 µH, 1.91 A, 2.91 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 4.3 µH
Rated Current Base 1.91 A
Saturation Current Base 2.91 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 65.6 µVs
DC Resistance Base 30 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196520
5.3 µH, 1.91 A, 2.53 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 5.3 µH
Rated Current Base 1.91 A
Saturation Current Base 2.53 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 65.6 µVs
DC Resistance Base 30 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196241
6.6 µH, 0.95 A, 1.55 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 6.6 µH
Rated Current Base 0.95 A
Saturation Current Base 1.55 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 48.3 µVs
DC Resistance Base 159 mΩ
Size ER14.5/6 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196541
7.6 µH, 1.7 A, 2.46 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 7.6 µH
Rated Current Base 1.7 A
Saturation Current Base 2.46 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 98.4 µVs
DC Resistance Base 71.1 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196341
7.9 µH, 0.97 A, 1.33 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 7.9 µH
Rated Current Base 0.97 A
Saturation Current Base 1.33 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 39.8 µVs
DC Resistance Base 140 mΩ
Size EFD15 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196231
8.3 µH, 0.95 A, 1.2 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 8.3 µH
Rated Current Base 0.95 A
Saturation Current Base 1.2 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 48.3 µVs
DC Resistance Base 159 mΩ
Size ER14.5/6 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196141
8.5 µH, 0.55 A, 0.96 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 8.5 µH
Rated Current Base 0.55 A
Saturation Current Base 0.96 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 32.9 µVs
DC Resistance Base 344 mΩ
Size ER11/5 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196331
9.3 µH, 0.97 A, 1.09 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 9.3 µH
Rated Current Base 0.97 A
Saturation Current Base 1.09 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 39.8 µVs
DC Resistance Base 140 mΩ
Size EFD15 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196531
9.7 µH, 1.7 A, 2.2 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 9.7 µH
Rated Current Base 1.7 A
Saturation Current Base 2.2 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 98.4 µVs
DC Resistance Base 71.1 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196510
9.9 µH, 1.91 A, 1.17 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 9.9 µH
Rated Current Base 1.91 A
Saturation Current Base 1.17 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 65.6 µVs
DC Resistance Base 30 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196131
10.9 µH, 0.55 A, 0.73 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 10.9 µH
Rated Current Base 0.55 A
Saturation Current Base 0.73 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 32.9 µVs
DC Resistance Base 344 mΩ
Size ER11/5 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196221
11.6 µH, 0.95 A, 0.84 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 11.6 µH
Rated Current Base 0.95 A
Saturation Current Base 0.84 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 48.3 µVs
DC Resistance Base 159 mΩ
Size ER14.5/6 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196521
12 µH, 1.7 A, 1.73 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 12 µH
Rated Current Base 1.7 A
Saturation Current Base 1.73 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 98.4 µVs
DC Resistance Base 71.1 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196321
14.2 µH, 0.97 A, 0.63 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 14.2 µH
Rated Current Base 0.97 A
Saturation Current Base 0.63 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 39.8 µVs
DC Resistance Base 140 mΩ
Size EFD15 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196121
14.7 µH, 0.55 A, 0.54 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 14.7 µH
Rated Current Base 0.55 A
Saturation Current Base 0.54 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 32.9 µVs
DC Resistance Base 344 mΩ
Size ER11/5 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196211
21.6 µH, 0.95 A, 0.36 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 21.6 µH
Rated Current Base 0.95 A
Saturation Current Base 0.36 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 48.3 µVs
DC Resistance Base 159 mΩ
Size ER14.5/6 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196511
22.3 µH, 1.7 A, 0.49 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 22.3 µH
Rated Current Base 1.7 A
Saturation Current Base 0.49 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 98.4 µVs
DC Resistance Base 71.1 mΩ
Size EFD20 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196311
23.3 µH, 0.97 A, 0.33 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 23.3 µH
Rated Current Base 0.97 A
Saturation Current Base 0.33 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 39.8 µVs
DC Resistance Base 140 mΩ
Size EFD15 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196111
27.4 µH, 0.55 A, 0.22 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 27.4 µH
Rated Current Base 0.55 A
Saturation Current Base 0.22 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 32.9 µVs
DC Resistance Base 344 mΩ
Size ER11/5 
Type gapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196500
87.1 µH, 1.91 A, 0.03 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 87.1 µH
Rated Current Base 1.91 A
Saturation Current Base 0.03 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 65.6 µVs
DC Resistance Base 30 mΩ
Size EFD20 
Type ungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196201
140 µH, 0.95 A, 0.02 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 140 µH
Rated Current Base 0.95 A
Saturation Current Base 0.02 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 48.3 µVs
DC Resistance Base 159 mΩ
Size ER14.5/6 
Type ungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196301
153.8 µH, 0.97 A, 0.02 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 153.8 µH
Rated Current Base 0.97 A
Saturation Current Base 0.02 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 39.8 µVs
DC Resistance Base 140 mΩ
Size EFD15 
Type ungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196501
196 µH, 1.7 A, 0.02 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 196 µH
Rated Current Base 1.7 A
Saturation Current Base 0.02 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 98.4 µVs
DC Resistance Base 71.1 mΩ
Size EFD20 
Type ungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196101
198.6 µH, 0.55 A, 0.01 A
Status Active i | Production is active. Expected lifetime: >10 years.
Inductance Base 198.6 µH
Rated Current Base 0.55 A
Saturation Current Base 0.01 A
Turns Ratio 1:1:1:1:1:1 
Insulation Test Voltage 500 V (AC)
Voltage-µSecond Base 32.9 µVs
DC Resistance Base 344 mΩ
Size ER11/5 
Type ungapped 

Comments

  • The WE-FLEX series of transformers consist of 6 independent windings which can be connected on the board as required. The 25 transformers facilitate more than 500 transformer and choke variants. The transformers still show an outstandingly low level of leakage inductance. Parts without airgap are especially designed for buck derived topologies like forward or push-pull converters. The high flexibility of the transformers allows developers to realize their own transformers without having to resort to a customer-specific transformer. Power levels of between 1 and 50 Watts can be transformed with the WE-FLEX series transformers. They can be used at switching frequencies of up to 1 MHz.
  • >