WE-FLEX Flexible Transformer for DC/DC Converter
SizeDimen­sions3DL
(mm)
W
(mm)
H
(mm)
ER11/5
12.9 13 6.2
ER14.5/6
16.3 16.8 7.4
EFD15
17.5 22.1 8.3
EFD20
21 29.5 10.8

Characteristics

  • Transformer with 6 identical windings
  • 4 sizes with 5 different lengths of air gap each
  • Isolation voltage 500 VDC
  • Low leakage inductance
  • Operating temperature: –40 ºC to +125 ºC
  • By using different circuits more than 375 transformer solutions and about 125 choke solutions possible. Consequently, quick prototyping possibilities

Applications

  • All kind of switching regulators
    - Flyback converters
    - Forward converters
    - Push-pull converters
    - Step-up/step-down converters
    - SEPIC converter

Can’t find the suitable product?

We will be glad to help you! We will take your specifications and work to find a solution that fits your needs. Simply fill out our inquiry form with your specifications.

Find your custom solution

Products

All
ER11/5
ER14.5/6
EFD15
EFD20
Filter article data
Filter by
 show  article in 4 product lines
 article in 4 product lines
Reset all
Order Code
Data­sheet
Downloads
Status
LBASE(µH)
IR BASE(A)
ISAT BASE(A)
n
VT(V (AC))
∫Udt Base(µVs)
RDC BASE(mΩ)
Size
Type
Samples
WE-FLEX Flexible Transformer for DC/DC Converter
749196540
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base3.4 µH
Rated Current Base1.91 A
Saturation Current Base4.18 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base65.6 µVs
DC Resistance Base30 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196530
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base4.3 µH
Rated Current Base1.91 A
Saturation Current Base2.91 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base65.6 µVs
DC Resistance Base30 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196520
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base5.3 µH
Rated Current Base1.91 A
Saturation Current Base2.53 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base65.6 µVs
DC Resistance Base30 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196241
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base6.6 µH
Rated Current Base0.95 A
Saturation Current Base1.55 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base48.3 µVs
DC Resistance Base159 mΩ
SizeER14.5/6 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196541
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base7.6 µH
Rated Current Base1.7 A
Saturation Current Base2.46 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base98.4 µVs
DC Resistance Base71.1 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196341
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base7.9 µH
Rated Current Base0.97 A
Saturation Current Base1.33 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base39.8 µVs
DC Resistance Base140 mΩ
SizeEFD15 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196231
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base8.3 µH
Rated Current Base0.95 A
Saturation Current Base1.2 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base48.3 µVs
DC Resistance Base159 mΩ
SizeER14.5/6 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196141
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base8.5 µH
Rated Current Base0.55 A
Saturation Current Base0.96 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base32.9 µVs
DC Resistance Base344 mΩ
SizeER11/5 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196331
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base9.3 µH
Rated Current Base0.97 A
Saturation Current Base1.09 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base39.8 µVs
DC Resistance Base140 mΩ
SizeEFD15 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196531
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base9.7 µH
Rated Current Base1.7 A
Saturation Current Base2.2 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base98.4 µVs
DC Resistance Base71.1 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196510
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base9.9 µH
Rated Current Base1.91 A
Saturation Current Base1.17 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base65.6 µVs
DC Resistance Base30 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196131
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base10.9 µH
Rated Current Base0.55 A
Saturation Current Base0.73 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base32.9 µVs
DC Resistance Base344 mΩ
SizeER11/5 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196221
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base11.6 µH
Rated Current Base0.95 A
Saturation Current Base0.84 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base48.3 µVs
DC Resistance Base159 mΩ
SizeER14.5/6 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196521
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base12 µH
Rated Current Base1.7 A
Saturation Current Base1.73 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base98.4 µVs
DC Resistance Base71.1 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196321
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base14.2 µH
Rated Current Base0.97 A
Saturation Current Base0.63 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base39.8 µVs
DC Resistance Base140 mΩ
SizeEFD15 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196121
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base14.7 µH
Rated Current Base0.55 A
Saturation Current Base0.54 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base32.9 µVs
DC Resistance Base344 mΩ
SizeER11/5 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196211
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base21.6 µH
Rated Current Base0.95 A
Saturation Current Base0.36 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base48.3 µVs
DC Resistance Base159 mΩ
SizeER14.5/6 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196511
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base22.3 µH
Rated Current Base1.7 A
Saturation Current Base0.49 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base98.4 µVs
DC Resistance Base71.1 mΩ
SizeEFD20 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196311
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base23.3 µH
Rated Current Base0.97 A
Saturation Current Base0.33 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base39.8 µVs
DC Resistance Base140 mΩ
SizeEFD15 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196111
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base27.4 µH
Rated Current Base0.55 A
Saturation Current Base0.22 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base32.9 µVs
DC Resistance Base344 mΩ
SizeER11/5 
Typegapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196500
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base87.1 µH
Rated Current Base1.91 A
Saturation Current Base0.03 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base65.6 µVs
DC Resistance Base30 mΩ
SizeEFD20 
Typeungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196201
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base140 µH
Rated Current Base0.95 A
Saturation Current Base0.02 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base48.3 µVs
DC Resistance Base159 mΩ
SizeER14.5/6 
Typeungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196301
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base153.8 µH
Rated Current Base0.97 A
Saturation Current Base0.02 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base39.8 µVs
DC Resistance Base140 mΩ
SizeEFD15 
Typeungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196501
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base196 µH
Rated Current Base1.7 A
Saturation Current Base0.02 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base98.4 µVs
DC Resistance Base71.1 mΩ
SizeEFD20 
Typeungapped 
WE-FLEX Flexible Transformer for DC/DC Converter
749196101
SPEC
Status Activei| Production is active. Expected lifetime: >10 years.
Inductance Base198.6 µH
Rated Current Base0.55 A
Saturation Current Base0.01 A
Turns Ratio1:1:1:1:1:1 
Insulation Test Voltage500 V (AC)
Voltage-µSecond Base32.9 µVs
DC Resistance Base344 mΩ
SizeER11/5 
Typeungapped 

Comments

  • The WE-FLEX series of transformers consist of 6 independent windings which can be connected on the board as required. The 25 transformers facilitate more than 500 transformer and choke variants. The transformers still show an outstandingly low level of leakage inductance. Parts without airgap are especially designed for buck derived topologies like forward or push-pull converters. The high flexibility of the transformers allows developers to realize their own transformers without having to resort to a customer-specific transformer. Power levels of between 1 and 50 Watts can be transformed with the WE-FLEX series transformers. They can be used at switching frequencies of up to 1 MHz.
  • >