IC-Hersteller Monolithic Power Systems

IC-Hersteller (96)

Monolithic Power Systems HR2000

Fluorescent Lamp HB Driver with PFC

Details

TopologieGegentaktwandler (Halbbrücken)
Eingangsspannung198-264 V
Schaltfrequenz96-108 kHz
Ausgang 155 V / 0.29 A
IC-Revision1.0

Beschreibung

The HR2000 is a fluorescent lamp ballast controller with PFC function and high voltage half+bridge driver. Only 16pin is used to offer cost effective solutions with minimized external components.The HR2000 can properly drive the two MOSFETs of half+bridge to control fluorescent lamp, ensuring all the features at the same time. The operating frequency is programmable and the sweeping frequency is controlled tolimit the preheat current. The preheat time and ignition time can be smartly set up for types of lamps and applications. Sufficient protection functions are provided for different fault modes such as over voltage, over current, over temperature, capacitive mode, end of life (EOL). Preheat driving signal is offered in preheat state to meet low power loss application which usually needs a MOSFET to cut off filament transformer.The PFC part only uses 4 pins to realize PFC function with On+time (Ton) control at boundary conduction mode (BCM). It is suitable for wideinput range. Over voltage protection and over current protection are integrated for the PFC part.The HR2000 is available in the 16+pin SOIC16 package.

Eigenschaften

PFC PART

  • Only four pins realize PFC function.
  • Ton control.
  • Boundary Conduction Mode operation.
  • Less peripheral components.
  • Over voltage and over current protection.

HALF-BRIDGE PART

  • 600V bootstrap half+bridge driver.
  • Programmable preheat current.
  • Programmable preheat time.
  • Programmable ignition time.
  • Single ignition attempt.
  • Over voltage protection.
  • Over current protection.
  • End+Of+Life protection
  • Capacitive mode protection.
  • Minimized external components.
  • Over temperature protection

Typische Anwendungen

  • Compact fluorescent lamp ballast
  • Tube fluorescent lamp ballast

Weiterführende Informationen

Artikeldaten

Artikel Nr. Daten­blatt Simu­lation Downloads ProduktserieL
(µH)
IR
(A)
ISAT
(A)
fres
(MHz)
VersionZ @ 100 MHz
(Ω)
Zmax
(Ω)
Testbedingung ZmaxIR 2
(mA)
RDC max.
(mΩ)
TypIR 1
(A)
L1
(mH)
RDC1 max.
(Ω)
VR
(V (AC))
VT
(V (AC))
MaterialL
(mm)
W
(mm)
H
(mm)
Montageart Muster
7447720222SPEC
8 Dateien WE-TI Tonneninduktivität 2200 0.29 0.35 1.1 Standard 4730 7.8 7.8 9.5 THT
7446121007SPEC
8 Dateien WE-LF Stromkompensierte Netzdrossel 6800 1 THT 300 1 6.8 0.3 250 1500 MnZn 18.5 13.5 20.5 THT
742792040SPEC
9 Dateien WE-CBF SMT-Ferrit 1.5 SMT 600 700 150 MHz 2000 150 High Current 2 0.15 2 1.2 0.9 SMT
Artikel Nr. Daten­blatt Simu­lation
7447720222SPEC
7446121007SPEC
742792040SPEC
Muster
Artikel Nr. Daten­blatt Simu­lation Downloads ProduktserieL
(µH)
IR
(A)
ISAT
(A)
fres
(MHz)
VersionZ @ 100 MHz
(Ω)
Zmax
(Ω)
Testbedingung ZmaxIR 2
(mA)
RDC max.
(mΩ)
TypIR 1
(A)
L1
(mH)
RDC1 max.
(Ω)
VR
(V (AC))
VT
(V (AC))
MaterialL
(mm)
W
(mm)
H
(mm)
Montageart Muster